If you want to use extra-alerting devices simultaneously, you need to plug the
modular cord for each device into a Line Bridging Adapter which you can
connect to either position (1) or position (2) on the bottom of the extra alert
switch.
For more information, contact your equipment dealer.
ADMINISTRATION
None
PROGRAMMING
None
HOW TO USE
To setup your SAA:
1 Unplug the appropriate voice terminal from its modular wall jack, and plug it
into the jack labeled V.T. on your SAA.
2 Plug one end of the modular cord into the jack labeled C.U. on the SAA and
the other end into the voice terminal’s modular wall jack.
3 Plug the modular cord from the extra alert device into the jack labeled
Alerter on the SAA.
To have the extra alert device turn on when a call rings at the appropriate
voice terminal, turn the SAA to the On position.
If you want to use more than one extra alert device alternately:
1 Turn the extra alert switch’s knob to the appropriate On position labeled
(1) or (2). For example, if you connect a bell to position (1) and a strobe to
position (2), turn the control switch to position (1) to operate the bell and to
position (2) to operate the strobe.
If you want to use more than one extra alert device simultaneously:
1 Turn the extra alert switch knob to the appropriate On position labeled
(1) or (2). For example, if you connect a bell and a strobe to a line bridging
adapter and the adapter to position (1) on the SAA, turn the control switch to
this position.
6-24 Accessory Equipment