PORT CIRCUIT PACKS
CO Trunk (TN447) — non-US Installations
The TN447 provides eight analog CO trunk ports. Each port has tip
and ring signal leads and connects to a two-wire analog line. The
TN447 has the following attributes:
Ground-start trunk signaling
50 Hz periodic pulse metering (PPM) detection and
counting
Administrable timers
CO Trunk (TN465 and TN465B) —
non-US Installations
The TN465 provides eight analog CO trunk ports and has the fol-
lowing attributes:
Loop-start trunk signaling
16 kHz PPM detection and counting
Administrable timers
The TN465B also provides battery reversed signaling.
CO Trunk TN747 or TN747B or C
Provides eight ports for loop-start or ground-start central office
(CO), foreign exchange (FX) and Wide Area Telecommunications
(WATS) trunks. A port can also be connected to a PagePac paging
system. Supports the Abandoned Call Search feature in automatic
call distribution (ACD) applications.