CONTROL CIRCUIT PACKS
Duplication Interface TN772 (G3iV2)
Selects the active processing element (control complex) in a dupli-
cated system and coordinates the interchange of processing ele-
ments. Controls and provides the memory shadowing function with
the duplication option. Terminates the environmental sensors and
controls the integrated battery supply and charging circuits. Selects
the active tone-clock circuit pack. Provides the G3-Management
Terminal interface in place of the processor. A second Duplication
Interface circuit pack resides in the duplicated control
carrier/cabinet. It requires a cable connection to the Duplication
Interface circuit pack in the basic control carrier/cabinet.
Duplication Interface UN330B (G3rV2)
In a duplicated system, which has two switch processing elements
(SPEs), one UN330B resides in each SPE and is connected to the
other UN330B. These provide control and communication paths
between the SPEs to keep the redundant standby (inactive) SPE
ready to assume control of the active SPE fails. The UN330Bs pro-
vide the following functions:
Selects active/standby mode for the two SPEs
Shadows (copies) the active SPE’s memory writes into
the standby SPE memory
Supports inter-SPE communication such as two-way
general purpose mailbox
Memory shadowing is a bidirectional high-speed path between the
two SPEs. When memory shadowing is activated, all shadowed
memory writes on the active processor's bus are sent across the
link and written into the standby processor's memory. Standby
memory writes are not sent to the active processor.