APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTION
POSSIBLE SOLUTION
6016: incorrect facility type The subtype number is the entered
subfacility type out of
type is too large for the facility
range
specified.
6017:
incorrect entry Traffic register number given is out
number out of range
of range.
6018:
incorrect action number
Item No. 3 is not applicable for the
incompatible with search
entered search type under item No.
1.
6020:
incorrect action number
Data entered for an item number is
can’t exceed 4 digits
greater than 4 digits and is not
acceptable.
6021:
incorrect entry
32 DGC groups/20 members per
DGC group number out
group. Can only be a member of 1
of range
group at a time.
6022:
inappropriate request
Cannot perform a search until the
must enter search data
data has been entered in item 3.
6023:
incorrect entry The entered alarm type is unknown.
type does not exist
6024:
incorrect action number
Item No. 2 is not applicable for the
incompatible with search entered search type under item No.
1.
6025:
incorrect entry Incorrect pattern number or
illegal character within
unexpected wild card character.
data See:
MENU = 8 (Search)
ACTION = 1 DATA = 21 or
ACTION = 2 DATA = 1-8
for more information.
7003: incorrect entry Data must be 1-31. See:
data must be 1-31
MENU = 4 (System)
ACTION = 3 and ACTION = 7
for more information.
7004: incorrect entry
Data must be 0-31. See:
data must be 0-31
MENU = 4 (System)
ACTION = 41
for more information.