MAINTENANCE
ERROR MESSAGE
AND DESCRIPTION
POSSIBLE SOLUTION
Unrecognized
Command:
Recoverable; no action required.
(STARLAN Interface CP) This
error is an
isolated transient
condition.
User Forced Warm Start: System
Recoverable; no action required.
was warm started through the
SAT.
Warm Start:
Power supply may be out of
System was restarted for some
regulation (see Figure 4-2). Check
reason; translations are okay.
remaining errors
in the alarm
tables for associated problems.
Wink Too Short For Valid Signal: Check equipment at far end to
For a delay dial or wink start ensure that it is working and
outgoing trunk, if the wink from
translated properly per Figure 4-3.
the far end is less than the
minimum 100 ms, this error is
generated. The tie trunk remains
waiting for a valid signal.
Work Cycle Interrupt Test Failed:
Try to warm start the system
Work cycle
interrupt problem.
through the SAT. If the problem
System most likely is stopped.
persists, check or replace the
CPU/Memory CP.
4-46