AT&T System 75And System 75XEUpgrades and Additions555-200-106Issue 5, October 1988
Description . . . . . . . . . . . . . . .207Procedure . . . . . . . . . . . . . . . .207REFERENCES . . . . . . . . . . . . . . . .208. . .-vli-
SMALL CABINET TO MEDIUM CABINET UPGRADE41.Remove the 631 power units and TN736 power unit from the smallcabinet control carrier A. Install them in the
SMALL CABINET TO MEDIUM CABINET UPGRADECABINETPORT CARRIER CI!PORT CARRIER BII II I1I I1CONTROL CARRIER ARESERVED FOR GROWTHTO A PORT CARRIER DRESERVE
SMALLCABINET TO MEDIUM CABINET UPGRADEFigure 22.Medium Cabinet TDM Bus Wiring Diagram90
SMALL CABINET TO MEDIUM CABINET UPGRADEPower Up SystemTo power up the system, do the following.Install Tape1.2.Operate3.4.5.Verify that the “write”arr
SMALL CABINET TO MEDIUM CABINET UPGRADEFigure 23.Switch Cabinet Circuit Breaker Location92
SMALL CABINET TO MEDIUM CABINET UPGRADEVerify Messages on the SAT6. Verify that screen displays the following:KEYBOARD LOCKED, WAIT FOR LOGIN7.After s
SMALL CABINET TO MEDIUM CABINET UPGRADEVERSION 2 or 3INVOKING EMERGENCY TRANSFERROM CHECKSUM TEST ( = BD9F )PASSEDSOFT INT TEST PASSEDMM/SD RAM TESTPA
SMALL CABINET TO MEDIUM10.If red lamps still do not go off, see AT&TMaintenance, 555-200-105, to clear trouble.CABINET UPGRADESystem 75—SystemAl
SMALL CABINET TO MEDIUM CABINET UPGRADE4. Label the tape just removed with the date and time it was created.This tape will be the backup and should
SMALL CABINET TO MEDIUM CABINET UPGRADE4. At the SAT, enter save translations. Press RETURN key.Screen displays:command successfully completed,enter c
FiguresFigure 1.Figure 2.Figure 3.Figure 4.Figure 5.Figure 6.Figure 7.Figure 8.Figure 9.Figure 10.Figure 11.Figure 12.Figure 13.Figure 14.Figure 15.Fi
SMALL CABINET TO5.6.7.8.9.10.Connect theMEDIUM CABINET UPGRADEpower cord to the HCMR thatwas removed from thesmall cabinet (an extension cord may be n
SMALL CABINET TO MEDIUM CABINET UPGRADE13.14.15.Remove tape cartridge from RMSS. Insert second RMSS tapecartridge. Verify that the “write” arrows on t
ADDITIONSADDITIONSThis section covers the procedures required to install additional features orequipment to an existing System 75 cabinet.All testing
ADDITIONSmFigure 24.Blank Circuit Pack Faceplate (Removal Slot Location)101
ADDITIONS1Figure 25.Blank Circuit Pack Faceplate102
ADDITIONSFigure 26.Typical System 75 TN-Coded Circuit Pack—Front View103
ADDITIONSTableA.J58890AA (System 75) Control Cabinet Circuit Pack LocationsIISlotDescriptionCodePositionIINoteMaintenance TN731(B) MAINTENANCE Proces
ADDITIONSTable A.J58890AA (System 75) Control Cabinet Circuit Pack Locations(Contd)SlotDescription CodePositionNoteAnalog Line (8 Port)TN7691-8Analog
ADDITIONSTable B.J58890AB (System 75) Control Cabinet Circuit Pack LocationsSlotDescriptionCodePositionNoteMaintenance TN731(B)MAINTENANCEProcessorTN7
ADDITIONSTable B.58890AB (System 75) Control Cabinet Circuit Pack Locations(Contd)SlotDescriptionCodePositionNoteHybrid LineTN762(B)1-12Analog Line (8
Figure 31.Figure 32.Figure 33.Figure 34.Figure 35.Figure 36.Figure 37.Figure 38.Figure 39.Figure 40.Figure 41.Figure 42.Figure 43.Figure 44.Figure 45.
ADDITIONSTable C.J58890BB (System 75) Port Cabinet Circuit Pack LocationsSlotDescriptionCodePositionNotePower UnitTN736POWER UNIT1Power UnitTN752POWER
ADDITIONSTable C.J58890BB (System 75) Port Cabinet Circuit Pack Locations(Contd)●SlotDescriptionCodePositionNoteMET LineTN7352-18Pooled ModemTN758 2-1
ADDITIONSTable D.J58890G (System 75 XE) Control Cabinet Circuit Pack LocationsSlotDescriptionCodePositionNoteTape DriveTN764TAPE DRIVE1ProcessorTN759P
ADDITIONSTable D.J58890G (System 75 XE) Control Cabinet Circuit Pack Locations(Contd)SlotDescriptionCodePositionNoteMET LineTN7351-143Tape DriveTN764T
ADDITIONSTable E.J58890H (System 75 XE) Port Cabinet Circuit Pack LocationsSlotDescriptionCodePositionNotePower Unit (V3)TN7551 1Tone DetectorTN748Bl
ADDITIONSTable E.J58890H (System 75 XE) Port Cabinet Circuit Pack Locations(Contd)Notes:1.When required, TN755 is located in slotposition 1.TN748B is
2. ADDA new portPORT CARRIERS (System 75 Only)carrier can be installed when additional features or equipmentexceed the capacity of the present system.
ADDITIONSInstall Port CarrierAt rear1.At front2.3.4.5.6.of cabinet—Remove blank port carrier panel.of cabinet—Remove blank port carrier panel by pushi
ADDITIONS11.12.13.b.c.d.e.f.g.h.Turn power unit on side. Operate rocker switches 1 through4 on DIP switch as follows:Switch631 B-type Position631A-typ
ADDITIONSPower Up System1.2.3.EnterAt the power distribution unit, set the main circuit breaker to ON.The system now goes through the rebooting proce
INTRODUCTIONINTRODUCTIONThis manual provides procedures and information for upgrading or makingadditions to an operational AT&T System 75 or Syste
ADDITIONSIPINSFigure 27.Blank Carrier Panel (Rear View)CONTROL CARRIER APORT CARRIER BREAR VIEW ( COVERS REMOVED)Figure 28.Grounding Jumper Locations
ADDITIONSCONTROL CARRIER ACABINETPORT CARRIER CPORT CARRIER BII1II1I11,PORT CARRIER DPORT CARRIER EREAR VIEW (COVERS REMOVED)Figure 29.Grounding Jumpe
ADDITIONSHCMRORRMSSFigure 30.One-Port CarrierWiring DiagramREAR VIEWConfigurationfor System Cabinet—TDMBus120
ADDITIONSHCMR OR RMSSREAR VIEWFigure 31.Two-Port CarrierWiring DiagramConfiguration for System Cabinet—TDM Bus121
ADDITIONSREAR VIEWFigure 32.Three-Port Carrier Configuration for System Cabinet—TDMBus Wiring Diagram122
ADDITIONSREAR VIEWFigure 33.Fully LoadedCabinet—TDM(4-Port Carrier) Configuration for SystemBus Wiring Diagram123
ADDITIONSPOWERCORDOUTLET631POWERBRUNITFigure 34.631BR Power Unit
ADDITIONS3. ADD PORT CABINET(S) (System 75 XE Only)One, two, or three port cabinets may be added to a control carrier whenadditional equipment or feat
ADDITIONSService InterruptionThe addition of port cabinets requires service interruption. The customershould be notified in advance when the addition
ADDITIONSFigure 35.Typical Power and Grounding Layout127
INTRODUCTIONORGANIZATIONThis manual is divided into ten sections. The remaining sections are asfollows:Ž•ŽŽ•••ŽŽUPGRADE PROCESS—SYSTEM 75UPGRADE PROCE
ADDITIONSFigure 36.AC Power Requirementsfor Multiple Cabinet Systems
ADDITIONSPosition Port Cabinets1.Remove the front door of each cabinet.a.Use a screwdriverclockwise one fourthb.Lift door from lowerand turn door latc
ADDITIONSDOOR LATCHFigure 37.Location of Cabinet Door Latch Screw130
ADDITIONSFigure 38.Four-Cabinet System—FrontPORT CABINET DPORT CABINET CCABINET CLIPCONTROL CABINET AView, Doors Removed131
ADDITIONSFigure 39.TDM Bus Connections132
ADDITIONSInstall Cabinet Address Plug(s)On the backplane of the port cabinets to the right of slot 00, a group of sixpins Is marked for the cabinet (c
ADDITIONSInstall Ground Plate(s)A ground plate is required between each cabinet (see Figures 41 and 42).The ground plate not only provides the ground
ADDITIONSSIDE VIEW2 CABINET SYSTEMFigure 41.Ground Plate and Cabinet Clip Location135
ADDITIONSREAR VIEWFigure 42.Ground Plate and Cable Clamps LocationInstall Cabinet Clip(s)A cabinet clip, used to stabilize the cabinets, is required b
ADDITIONSWarning:A wrist strap must always be worn, and the clipmust be grounded to the cabinet frame beingworked on before inserting or removing anyc
UPGRADE PROCESS SYSTEM 75UPGRADE PROCESS SYSTEM 75This section provides the information necessary to upgrade the System 75from a Release 1, Version 1
ADDITIONSEnter Added TranslationsEnter added translation data asImplementation, 555-200-651, and200-500.Save Translationsapplicable usingthe AT&T
ADDITIONS2.3.4.5.6.7.8.9.10.11.12.13.14.TILTWATCH indicators are normally white. If the box has beenshocked or tilted, the indicators will be red, ind
ADDITIONS15.16.17.18.Position19.20.Place the ramps at end of pallet in line with the rear cabinet casters(Figure 43).Stand between the ramps. Hold’ bo
ADDITIONS21.22.23.f. Install hardware for securing cabinet to floor according to— computer— concrete— woodg.Tighten bolts. If earthquake mounting is n
ADDITIONSFigure 43.Pallet-Mounted Auxiliary Cabinet
ADDITIONSFigure 44.Ramps Installedon Pallet
ADDITIONSFigure 45.Auxiliary Cabinet144
ADDITIONS5. ADD ATTENDANT CONSOLERequirementsThe attendant console is connected toconnecting block) the same as any otheran informationvoice terminal.
ADDITIONS6.7.8.9.10.Install handset bracket on left or right side of console, as desired.Insert handset adapter on same side of handset bracket.Note:T
ADDITIONSFigure 46. SelectorConsoleInstallation147
UPGRADE PROCESS SYSTEM 75The three required, circuit packs and a brief description of each are containedin the following list.• TN711BThe Processor ci
ADDITIONS7. ADDCO, FX, WATS, AND PCOL TRUNKSRequirementsCentral Office (CO), ForeignService (WATS), or PersonalExchange (FX), Wide Area Telecommunicat
ADDITIONSInstallation1.2.3.Determine port assignment of trunk from Trunk Group Form.EXAMPLE: Port NumberA07 01Carrier/Slot CircuitCabinetSee “Add Circ
ADDITIONS4. Administer forms listed under Tie Trunk Group in the AT&T System75—implementation, 555-200-650 (RIV1 ) or AT&T System 75 andSyste
ADDITIONSTable F.TN760B Option Switch Settings and AdministrationSystem 75/75 XEInstallationSituationCircumstanceColocatedInter-Bldg.ColocatedInter-B
ADDITIONS10. ADDDS1 TIE TRUNK SERVICEThe TN722B DS1 Tie Trunk circuit pack provides connection capability to a1.544 Mbps DS1 facility as 24 independen
ADDITIONSPower Down SystemSystem 751.At the maintenanceCONTROL switch tomode.board, set theON. This locksEMERGENCY TRANSFERthe system in the transfer2
ADDITIONSInstall CablesInstall cables from cabinet to cross-connect field as required.Detailed descriptions for installing wiring are contained in the
ADDITIONSEnter Added Translations1.Administer forms listed under DSI Tie TrunkSystem 75 and System 75 XE—implementation,555-200-652 (RIV3).Save Transl
ADDITIONSRequirementsA TN763 or TN763B Auxiliary Trunk circuit pack must be connected andinstalled for Loudspeaker Paging. The Code Calling Access fea
ADDITIONS14. ADD OFF-PREMISES ANDOUT-OF-BUILDING TERMINALSRequirements—Off-Premises Terminalsoff-premises terminals are those extensions that are not
UPGRADE PROCESS SYSTEM 75Ž TN726The Data Line circuit pack is required to provide direct connection toEIA RS-232C terminals and host ports, including
ADDITIONSDetailed descriptions for installing wiring are contained in the AT&T System75—Wiring, 555-200-111.15. ADD EXTERNAL RINGINGRequirementsEx
ADDITIONS16. ADD QUEUE WARNING INDICATORRequirementsAn ac indicator (lamp) such as a 21C49 is optional for use as a queuewarning indication in a Unifo
ADDITIONSInstallation1.2.3.Determine port assignment of paging zone(s) from LoudspeakerPaging Form:EXAMPLE: Port NumberB02 01Carrier/Slot CircuitCabin
ADDITIONSThree models are available:Ž PagePac 20Ž PagePac VSŽ PagePac 50/100/200PagePac 20The PagePac is a 20-watt amplifier that can be used alone to
ADDITIONSInstallation1.Determine port assignment of paging zone(s) from LoudspeakerPaging Form:EXAMPLE: Port NumberB02 01Carrier/Slot CircuitCabinet2.
ADDITIONS19. ADD MUSIC-ON-HOLD ACCESSRequirementsAccess to the music source is provided by an information outlet.A TN763 or TN763B Auxiliary Trunk cir
ADDITIONS20. ADD LOUDSPEAKERWITH BACKGROUNDRequirementsBackground music may be added afterPAGINGMUSICthe Loudspeaker Paging and Music-on-Hold features
ADDITIONSInstallation1.2.3.Determine port assignment of feature from Announcement Form:EXAMPLE: Port NumberB02 01Carrier/Slot CircuitCabinetSee “Add C
ADDITIONS23. ADD RECORDED TELEPHONEDICTATION ACCESSRequirementsAccess for recorded telephone dictation equipmentinformation outlet.For analog trunk ac
ADDITIONS24. ADD INADS INTERFACERequirementsThe interface between System 75 and System 75 XEAdministration System (INADS) is through a 2-wayMaintenanc
UPGRADE PROCESS SYSTEM 75If Station Message Detail Recording is provided and a TELESEER® StationMessage Detail Recorder (SMDR) unit is used as the out
ADDITIONSThe MPDMs are connected to TN754 Digital Line circuit packs and aremounted individually or in a 71A data mounting. The MPDM installation andt
ADDITIONSAdd Circuit Packs1.Determine port assignment of, circuit packs to be added.2. See “Add Circuit Packs,” and install the appropriate circu
ADDITIONSAdminister the other required translation data using the forms listed underApplications Processor (AP) Interface and Assignments in the AT&am
ADDITIONSInstallation1.For the direct access method (System 75 XE only), connect EIA cordto DCE connector at rear of control cabinet (see Figure 48).
ADDITIONS27. ADDEMERGENCY TRANSFERRequirementsTwo emergency transfer panels are available:Ž Z1A Panel—Each unit serves up to six Power Failure Transf
ADDITIONS28. ADD INFORMATION SYSTEMNETWORK INTERFACERequirementsThe interface between System 75 and 75 XE andNetwork (ISN) is through an Asynchronous
ADDITIONS29. ADD3270 DATA MODULERequirementsThe 3270 Data Module consists of a family of protocol converters that allow3270-type terminals to communic
ADDITIONS31. ADD CALL MANAGEMENT SYSTEM (CMS)INTERFACERequirementsThe interface between System 75 and System 75 XE and the CMS is througha modular pro
ADDITIONSSave Translations1.Login at the System Access Terminal (SAT).2. Enter save translations.Press the RETURN key. This commandinstructs the sys
ADDITIONS,Add Circuit Packs1.2.InstallDetermine port assignment of circuit packs to be added.EXAMPLE: Port NumberB02 01Carrier/Slot CircuitCabinetSee
UPGRADE PROCESS SYSTEM 75Applications Processor Software UpgradeTranslation data must be upgraded to establish a communications path forthe AP. Refer
ADDITIONSSystem 75XE1.At the rear of each cabinet on the back of the power supply, set thecircuit breaker to ON.2. The system now goes through the r
ADDITIONSinformation is contained in the AT&T System 75—Modular Trunk Data Module,999-700-301.For the System 75, the communications interface is p
ADDITIONSPower Down SystemSystem 851.At the maintenanceCONTROL switch tomode.board, set the EMERGENCYON. This locks the system inTRANSFERthe transfer2
Sixteen ports on TN742 or TN769 Analog Line circuit packs arerequired.A vacant port is required on a TN754 Digital Line circuit pack.Install CablesIns
ADDITIONSEnter Added TranslationsAdminister the required translation data using the forms listed under AudioInformation Exchange (AUDIX) Interface and
ADDITIONSInstallation1.Determine port assignment from Data Module Form:EXAMPLE: Port NumberB02 01Carrier/Slot CircuitCabinet2. See “Add Circuit Pack
ADDITIONSŽ If the TN736 Power Unit is used, each half carrier (slots 01 through10 and 11 through -20) can support a maximum of five TN746 circuitpa
ADDITIONS11.Type in a “list configuration board” command or a “display circuit-packs” command to verify that the resident board is recognized as aTN74
ADDITIONSVerify System StatusSince the system should be alarmbefore proceeding, and all problemsSave Translationsfree, it shouldcorrected.be examined
The TN716 Interface 1, TN738 Interface 2, and TN719 Interface 3circuit packs are required.The TN760B or TN722B DS1 Tie Trunk circuit packs are require
TO ORDER COPIES OF THIS MANUALCall: AT&T Customer information Center on 800-432-6600In Canada Call 800-255-1242Write: AT&T Customer Informatio
UPGRADE PROCESS SYSTEM 75Ž Maintenance tests in VI on analog stations could be disabled using“write physical byte.”In V2, a question “Tests?” which, i
ADDITIONSInstall CablesInstall cables from cabinet to cross-connect field as required.Detailed descriptions for installing wiring are contained in the
ADDITIONSOn the System Parameters-Customer Options Form, set the DistributedCommunications System (DCS) field to “y” to enable the feature.Administer
TESTSTESTSThe tests in this manual are performed after customer’s translations havebeen entered and all wiring and connections have been made.The foll
TESTS5.6.7.DialDialtrunk access code.Requirement: System dial tone is heard.listed directory number for another working voice terminal.Requirement:
TESTS4. Dial number associated with a working voice terminal.Audible ringing tone is heard in earpiece.5. Press ReleaseAudible ringing tone is sile
TESTSTest External RingingDescriptionMake test call to attendant console to verify that ringing device sounds whenNight lamp on console is lighted. If
TESTS6.7.8.9.10.11.TestVerify that ringing is heard on spare voice terminal.At test terminal, go on-hook.Disconnect spare voice terminal from informat
TESTS6. At test terminal, go on-hook.7.Administer queue warning threshold number to number changed instep 1.8.Restore service to all terminals made
TESTSTestRecorded Intercept AnnouncementDescriptionMake call using a trunk access code and an invalid extension number toverify that recorded announce
TESTS3. When recording isor hang up if usingRequirement:complete, dial“#” if using hybrid voice terminalanalog or digital voice terminal.Recording sto
UPGRADE PROCESS SYSTEM 753. Prerequisite HardwareBefore the system can be upgraded to Version 2, the following items must beat the customer’s site:1.2
TESTSProcedure—Dial Dictation Equipment Installed1.Select working voice terminal as test terminal and2. Dial access code and number associated with
TESTSProcedure1.2.3.4.5.Select working voice terminal as test terminal.At test terminal, go off-hook and dial trunk access code for aparticular zone.R
TESTS5.6.TestVerify that music is heard at test terminal.At test terminal, go on-hook.Emergency TransferDescriptionPut system in emergency transfer mo
TESTSTest INADS InterfaceDescriptionTest the communication link between the System 75 and INADS and verifythe alarm notification process.system and a
TESTSProcedure—Local Test1.2.3.4.Login and enterRequest INADSCheck error logTerminate Iogin.Test Tie TrunksDescriptiontest inads-link command.personne
TESTS,4.Verify that ringing tone is silenced at distant end and conversation isgood.5. At test terminal, go on-hook. 6. At distant terminal, go on
TESTS2.3.4.At test terminal, go off-hook.Requirement:Tones are silenced and conversation isgood. At test terminal, go on-hook.At distant terminal, go
TESTSProcedure1.2.3.4.5.Select a working voice terminal as a test terminal.Arrange an incoming call to the test terminal on the DID trunk to betested.
TESTS3.4.5.6.7.Dial number of desired trunk party.Requirement:Dial tone silenced.At distant party, go off-hook.Verify that ringing tone is silenced at
TESTSTest Duplication Option Processing Element (PE)InterchangeDescriptionThe process of the standby PE taking over for the active PE is referred to a
UPGRADE PROCESS SYSTEM 754. Service InterruptionThe Version 2 upgrade requires service interruption. The customer should benotified in advance when th
REFERENCESREFERENCESThe following is an abbreviated listing of System 75 documents. Included isa brief description of each document in the list. For a
REFERENCESAT&T System 75—Upgrades and Additions555-200-106Provides procedures and information required to upgrade an RI VI System 75to a R1V2 or R
REFERENCESAT&T System 75—lmplementation—Release 1 Version 1555-200-650Provides the procedures and associated forms for collecting system andtermin
REFERENCESAT&T System 75—Hospitality OperationsContains the procedures for using the Hospitality Services75, Release 1 Version 3. These services i
REFERENCESUser instruction booklets are also available for all terminals used with System75 and System 75 XE.212
INDEXINDEXAAbbreviated Dialing Software Upgrade 7Add 16-Port Analog Line Circuit Pack 183to Replace Two 8-Port Analog Line CircuitPacks 183Add 3270 Da
INDEXBasic V2 to V3 Upgrade 29CChange Extensions or Access CodesBeginning With O 36, 50CO TrunkTest 205Code Calling Test 198Create Tape Backup 27DDID
INDEXSSelector Console Test 192Service Interruption 10, 34, 48Small Cabinet Control Carrier Upgrade 66Small Cabinet to Medium Cabinet Upgrade 70Softwa
UPGRADE PROCESS SYSTEM 755. Procedures Required To Upgrade Version 1 to Version 2The following procedures must be followed to upgrade a System 75 fro
UPGRADE PROCESS SYSTEM 752. Screen displays the configuration report for the circuit packsinstalled in the system. The TN711 Processor circuit pack mu
UPGRADE PROCESS SYSTEM 757.8.9.10.11.With the notched end of IC30 (PID ABFGT) facing left toward circuitpack connector, insert the IC30 socket making
UPGRADE PROCESS SYSTEM 75FigurePORT CARRIER (C)J58890BBPORT CARRIER (B)J58890BBCONTROL CARRIER (A)J58890AAFAN ASSEMBLY (X)ED-67077PORT CARRIER (D)J588
UPGRADE PROCESS SYSTEM 75●FAN ASSEMBLY (X)ED-67077CONTROL CARRIER (A)J58890AA OR J58890AB(SEE NOTE 1 )PORT CARRIER (B)J58890BB(SEE NOTE 2)POWERDISTRIB
UPGRADE PROCESS SYSTEM 75CONTROL CARRIER (J58890AA)CONTROL CARRIER (J58890AB)NOTES :1.2.3.4.INTERFACE 1 TN716, INTERFACE 2 TN720/TN738 (V2 OR V3), And
UPGRADE PROCESS SYSTEM 75NOTES :1.2.Figure 4.IN ADDITION TO THE TN748/TN748B TONE DETECTOR LOCATED INTHE CONTROL CARRIER, MODEL 1B, 2B, AND 3A SYSTEMS
ContentsINTRODUCTION . . . . . . . . . . . . . . .1PURPOSE . . . . . . . . . . . . . . . . .1ORGANIZATION . . . . . . . . . . . . . . .2UPGRADE PROCE
IIC30Io00Figure 5.TN748 Tone Detector Circuit Pack IC30 Location (ComponentSide)18
UPGRADE PROCESSRemove, Upgrade, Replace, and Test TN711 Circuit PackSYSTEM 75The TN711 Processor circuit pack must be vintage 11 or 12 and must beknow
UPGRADE PROCESS SYSTEM 756.7.8.9.10.With the notched end of IC38 (PID ABFJH) facing left toward thecircuit pack connector, insert the IC38 socket maki
UPGRADE PROCESS SYSTEM 75Figure 6.Maintenance Board IndicatorsFigure 7.Power Distribution Unit21
UPGRADE PROCESS SYSTEM 75Figure 8.TN711 Processor Circuit Pack IC38 and IC39 Location(Component Side)22
UPGRADE PROCESS SYSTEM 75Install and Test TN734 Memory Circuit PackThis circuit pack is not a replacement for the existing TN734 Memory circuitpack. T
UPGRADE PROCESS SYSTEM 752. The system now goes through the rebooting process, loading thesystem program and translations from the tape. Rebooting
UPGRADE PROCESS SYSTEM 75,Power Up SystemAfter the new circuit pack has been installed, power up the system asfollows:1.2.3.Set the main circuit break
UPGRADE PROCESS SYSTEM 75,Remove and Install Tape Cartridge1.2.Reload1.2.AssignRemove the Version 2 tape cartridge.Install the Version 1 tape cartridg
UPGRADE PROCESS SYSTEM 75Forced Entry of Account CodesUniform Dial Plan• Voice Terminal• Date and TimeCreate Tape BackupFeaturesA Version 2 backup tap
PREREQUISITE HARDWARE . . . . . . . . . . . . 56PROCEDURE FOR UPGRADES . . . . . . . . . . . 57SMALL CABINET CONTROL CARRIER UPGRADE . . 66PREREQUISI
UPGRADE PROCESS SYSTEM 759.10.11.12.13.Update1.Label the Version 2 tape cartridge just removed with the date andtime it was created. A special notatio
UPGRADE PROCESS SYSTEM 75Basic V2 to V3 UpgradeThe basic V2 to V3 upgrade mayReplacing the softwareeither HCMR or RMSS.Replacing the TN731requiretape.
UPGRADE PROCESS SYSTEM 75The two optional circuitcontained in the followingŽ TN761packs and a brief description of each islist. The 4-megabyte Memory
UPGRADE PROCESS SYSTEM 75Ž TN763BThe AuxiliaryannouncementŽ TN769Trunk circuit pack supports Audichron*equipment.The Analog Line circuit pack provides
UPGRADE PROCESS SYSTEM 75The V3 administration of recorded announcements requires:Ž Completing of the Announcements FormŽ Assigning a recorded announc
UPGRADE PROCESS SYSTEM 75The following features are part of the basic Version 3 software package anddo not need to be activated (they are defaulted to
3.4.5.• TN747B—COTrunkŽ TN750—Announcement• TN752—Power Unit—The J58890BB portList 2 to support the TN752 Power Unit.must be replaced.carrier mus
UPGRADEThe following features, if activated, are deactivated:PROCESS SYSTEM 75Attendant Trunk Group ControlAutomatic CallbackCall ForwardingCall ParkM
UPGRADE PROCESS SYSTEM 75Print Out and Remove Hunt GroupsIf the hunt groups are being measured by the Automatic Call Distributionfeature under Call Ma
UPGRADE PROCESS SYSTEM 752. Enter the new dial plan.3. Depress Enter. You will, receive the response commandsuccessfully completed.Save Translations1
3.4.5.6.7.8.9.Save Translations . . . . . . . . . . .
UPGRADE PROCESS SYSTEM 752. Install the TN731B Maintenance circuit pack in the slot the TN731was removed from.Remove TN734 and Install TN761 Memory Ci
UPGRADE PROCESS SYSTEM 756.7.8.9.10.11.12.Install the new port carrier in the cabinet. Insert and tighten the fourretaining screws.Connect all ground
UPGRADE PROCESS SYSTEM 75Add or Replace Circuit PacksAdd orPower1.2.3.replace circuitUp SystemSet the mainThe systempacks for the new Version 3 featur
UPGRADE PROCESS SYSTEM 75Save Translations1.Log in at the SAT.2. Enter save translations, and press the RETURN key. Thiscommand instructs the system
UPGRADE PROCESSSave Translations1.2.Enter saveSYSTEM 75translations,and press the RETURN key. Thiscommand instructs the system to take all translation
UPGRADE PROCESS SYSTEM 758.Update1.All Version 1 or 2 tapes should be removed so that the customeronly has Version 3 tapes.Port Assignment RecordUpdat
UPGRADE PROCESS SYSTEM 75 XEUPGRADE PROCESS SYSTEM 75 XEThis section provides the information necessary to upgrade the System 75XE from a Release 1, V
UPGRADEPROCESS SYSTEM 75 XEŽ TN769 Analog line circuit pack—Provides eight ports for on-premises (in building) or off-premises (out of building) anal
UPGRADE PROCESS SYSTEM 75Ž Assigning a recordedcoverage point (Point1,Coverage Paths Form.XEannouncement extension number to aPoint2, Point3) as requ
UPGRADE PROCESS SYSTEM 75 XEŽ Emergency Access to the AttendantŽ HospitalityŽ Service Observing.Upgrading or making an addition may require changes to
Add Circuit Packs . . . . . . . . . . . . . . . .Install Cables . . . .
UPGRADE PROCESS SYSTEM 75 XEŽ Two Version 3 tape cartridges. One tape is used for systemoperation and one for system backup.Ž One copy of eac
UPGRADE PROCESS SYSTEM 75 XEThe numbers stored by the Last Number Dialed feature are lost. In addition,any translation data enteredincludes Abbreviate
UPGRADE PROCESS SYSTEM 75 XE2. Enter the display hunt-group (1-32) print command for each huntgroup.3. Enter the remove hunt-group (1-32) command for
UPGRADEPower Down SystemPROCESS SYSTEM 75 XE1.At the Processor circuit pack, set the EMERGENCYCONTROL switch to ON. This locks the system inmode.TRANS
Remove and InstallSYSTEM 75 XETape Cartridge1.Remove the Version 2 tape cartridge.2. Install the Version 3 tape cartridge making sure the “write” arro
UPGRADE PROCESS SYSTEM 75 XE2. Install the Version 3 tape cartridge making sure the “write” arrowpoints away from the SAFE position.Save Translations1
UPGRADE PROCESS SYSTEM 75 XEŽ Voice Terminal Features● Date and Time.Save Translations1.Enter save translations, and press the RETURN key. Thiscommand
UPGRADE PROCESS SYSTEM 75 XE6.7.8.Update1.Label the Version 3 tape (removed in Step 1 ) with the date and timeand a special notation to clearly distin
REMOVABLE MASS STORAGEREMOVABLE MASS STORAGESUBSYSTEM UPGRADEThe Removable Mass Storage Subsystem (RMSS) is not required for theRelease 1 Version 2 or
REMOVABLE MASS STORAGE SUBSYSTEM UPGRADEŽ 1/8-inch drill bit.Ž Spring loaded center punch.Ž Allen wrenches.Ž Masking tape.The following circuit packs
Install Cables . . . . . . . . . . . . . . . . . . . . . . .Power Up System . . . . . . .
REMOVABLE MASS STORAGE SUBSYSTEM UPGRADE,Ž At the power distribution unit, set the main ac circuit breakerto OFF.4.Disconnect System 75 main power plu
REMOVABLE MASS STORAGE SUBSYSTEM UPGRADE6.7.8.9.10.11.12.13.14.15.16.17.See WARNING. If required, install TN711B, TN729 vintage 4 orhigher, and TN734
REMOVABLE MASS STORAGE SUBSYSTEM UPGRADE18.19.20.21.Replace side plate on power distribution unit, and secure withscrews.Install RMSS unit, and secure
REMOVABLE MASS STORAGE SUBSYSTEM UPGRADESLOT 22RMSSAC POWERCORD FLATRIBBONSIGNAL<CABLE1REAR VIEW ( COVERS REMOVED)‘ CARRIER AHF4CIRCUITCONNECTORSL
REMOVABLE MASS STORAGE SUBSYSTEM UPGRADE22. At front ofend to one23.ReconnectŽ AtHCMR on floor, connect ac power cord. Connect otherof the System 75 c
REMOVABLE MASS STORAGE SUBSYSTEM UPGRADEFigure 12.Power Distribution Unit26.See DANGER. Disconnect flat ribbonto HCMR.(Cover Removed)—With RMSScable f
REMOVABLE MASS STORAGE SUBSYSTEM UPGRADE30.31.32.33.Log in at the SAT, and enter save translations. Press RETURN key.Screen displays:command successfu
REMOVABLE MASS STORAGE SUBSYSTEM UPGRADE37. Power up system:Ž At the power distribution unit, set the main ac circuit breakerto ON.Ž The system n
SMALL CABINET CONTROL CARRIERSMALL CABINET CONTROL CARRIERUPGRADEThe J58890AB control carrier in the System 75 small cabinet can beupgraded to a J5889
SMALL CABINET CONTROL CARRIER UPGRADE2.3.Power1.2.3.Enter save translations. Press the RETURN key. This commandinstructs the system to take all transl
34. ADD 16-PORT ANALOG LINE CIRCUIT PACKTO REPLACE TWO 8-PORT ANALOG LINECIRCUIT PACKS . . . . . . . . . . . . . . . . . . . . .
6.7.8.9.10.11.12.Power1.2.3.Install the new control carrierfour retaining screws.Connect all ground straps andUPGRADEin the cabinet. Insert and tighte
4.5.6.7.8.Enter new translations as required. This upgrade will usually be inSMALL CABINET CONTROL CARRIER UPGRADEconjunction with the addition of AU
SMALL CABINET TO MEDIUM CABINET UPGRADESMALL CABINET TO MEDIUM CABINETUPGRADEThe small System 75 cabinet can be upgraded to a medium cabinet when thes
SMALL CABINET TO MEDIUM CABINET UPGRADEŽ One 631AR, 631WA1, or 631DA1 Power UnitŽ One 631BR, 631WB1, or 631DB1 Power UnitŽ One TN736 Power Unit● 20 B2
●●●SMALL CABINET TO MEDIUM CABINET UPGRADEAdditional information on the CSSO INADS upload/downloadtranslation process may be obtained from your local
SMALL CABINET TO MEDIUM CABINET UPGRADE7. Screen displays:commandsuccessfully completed,enter command:Verify That Site Is Ready for New1.Verify that t
SMALL CABINET TO MEDIUM CABINET UPGRADEFigure 13.Small Cabinet and Medium Cabinet Carrier Layouts74
SMALL CABINET TO MEDIUM CABINET UPGRADEReplace Small Cabinet With Medium CabinetSee DANGER. The medium cabinet Is shipped in a polyethylene bag, packe
SMALL CABINET TO MEDIUM CABINET UPGRADE5.Use a No. 10 slot screwdriver to turn clockwise the screws locatedon door to release latches and open cabinet
SMALL CABINET TO MEDIUM CABINET UPGRADEFigure 14.Location of 5-Carrier Switch Cabinet Door Latches77
Test Integrated Announcement .Description . . . . . . . .. . .. . .Test Recorded Telephone Dictation Access .Description . . . . .Procedure—Dial Dicta
SMALL CABINET TO MEDIUM CABINET UPGRADE10.11.12.13.14.15.16.17.18.19.Remove the ramps that are stored under the cabinet (see Figure 15).Remove the 115
SMALL CABINET TO MEDIUM CABINET UPGRADEFigure 15.Pallet-Mounted System 7579
SMALL CABINET TO MEDIUM CABINET UPGRADEFigure 16.Ramps Installed on Pallet
SMALL CABINET TO MEDIUM CABINET UPGRADECheck Equipment and Circuit Pack Configuration20.Verify that all circuit packs are fully seated in proper slots
SMALL22.23.24.CABINET TO MEDIUM CABINET UPGRADEIf earthquake mounting is not provided, adjust and lock the two 2-1/2inch stabilizing bolts at front of
SMALL CABINET TO MEDIUM CABINET UPGRADE CABINET (REAR VIEW)Figure 17.Location of 5-Carrier Cabinet Cable Clamps83
SMALL CABINET TO MEDIUM CABINET UPGRADEDisconnect the Small and Connect the Medium Cabinet26.27.28.29.30.31.Remove the top rearAt the small cabinetbre
SMALL CABINET TO MEDIUM CABINET UPGRADE32. At the small cabinet, do the following-- Ž Remove the two rear bottom panels of the
SMALL CABINET TO MEDIUM CABINET UPGRADECABINETCONTROL CARRIER APORT CARRIER BREAR VIEW (COVERS REMOVED)Figure 20.Small Cabinet Grounding Jumper Locati
SMALL CABINET TO MEDIUM CABINET UPGRADE33.34.35.36.37.38.39.40.See Warning.Remove all the circuit packs from the port carrier ofthe small cabinet. Ins