Vista de pagina 35
2-4 Dedicated EIA RS-232 Networks
________________________________________________________________________________________________
________________________________________________________________________________________________
________________________________________________________________________________________________
AUDIX
AUDIX
AUDIX
SWITCH
RS-232
RS-232
RS-232
RS-232
RS-232
RS-232
CALL DETAIL
RECORDING
H600-330
GROUP 1
H600-331
GROUP 2
H600-331
GROUP 2
H600-331
GROUP 2
MODEM
MODEM
MODEM
MODEM
MODEM
Figure 2-4. Dedicated RS-232 Network of Three AUDIX Systems and a PC
AUDIX REQUIREMENTS FOR DEDICATED RS-232
Each AUDIX system must be running R1V5 or later software. Each AUDIX must be equipped with a
TN539 or TN539B ACCE circuit pack. The AUDIX Networking Breakout cable (H600-331, Group 2) and
the special AUDIX null-modems (H600-330, Group 1) are provided with each TN539 or TN539B ordered.
NOTE
Standard null-modems cannot be substituted for the AUDIX null-modems.