DCS Administration
4-20 Issue 1 October 1997
261 Word 1
Assign Call Transfer Into INTUITY AUDIX.
Press and .
261 Word 2
Administer the external network adjunct extension.
Press and .
350 Word 2
Assign a dial access code to feature code 58.
Press and .
1. Enter the same number as in Procedure 261, Word 1.
2. From Worksheet C: Assign the INTUITY AUDIX Split.
Field Manager II Field Name Enter
1 Local Adjunct Class 2
2 Local Adjunct Number 1
3 Local Adjunct Type 3
7 Network Adjunct Number [1–99]
Field Manager II Field Name Enter
1 Network Adjunct Class 2
2 Network Adjunct Number
1
3 Adjunct Extension [INTUITY AUDIX system
extension]
2
Field Manager II Field Name Enter
1Feature 58
2 Digit 1 [first # of DAC]
3 Digit 2 [second # of DAC]
4 Digit 3 [third # of DAC]
5 Digit 4 [fourth # of DAC]
ADD
EXECUTE
CHANGE
EXECUTE
ADD
EXECUTE