ENVIRONMENTAL REQUIREMENTS
(System 75 and G1 multi-carrier cabinet)
CABINET
Fully Loaded 5-Carrier (Medium) 800 Lbs 70"x32"x24"
Fully Loaded 2-Carrier (Small)
400 Lbs
42"x32"x24"
Fully Loaded 5-Carrier (PPN or EPN) (G1)
800 Lbs
70"x32"x28"
HEAT DISSIPATION
8000 BTU/HR
Fully Loaded 5-Carrier
(V1, V2, V3, G1)
4000 BTU/HR
Fully Loaded 2-Carrier
(V1, V2, V3)
5000 BTU/HR
Average 5-Carrier
(V1, V2, V3, G1)
2500 BTU/HR
Average 2-Carrier
(V1, V2, V3)
AC POWER REQUIREMENTS
115 Volts 50-60Hz
50 Amps 5-Carrier (Medium)
115 Volts
50-60Hz
20 Amps 2-Carrier (Small)
115 Volts
50-60Hz
208 Volts 50-60Hz
DC POWER REQUIREMENTS
-48 Volts
66 Amps (G1)
TEMPERATURE/ROOM HUMIDITY RANGE
40° To 110°F.
10% to 95% Relative Humidity at 84°F
10% to 45% Relative Humidity at 110°F