AT&T DataPort PCX Modem Guía de usuario

Busca en linea o descarga Guía de usuario para Módems AT&T DataPort PCX Modem. AT&T DataPort PCX Modem User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 89
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
You have accessed an
older version of a
Paradyne product
document.
Paradyne is no longer a
subsidiary of AT&T. Any
reference to AT&T
Paradyne is amended to
read Paradyne
Corporation.
AREA CODE CHANGE
Please note that the area
code for Paradyne
Corporation in Largo,
Florida has changed from
813 to 727.
For any Paradyne
telephone number that
appears in this manual
with an 813 area code,
dial 727 instead.
Vista de pagina 0
1 2 3 4 5 6 ... 88 89

Indice de contenidos

Pagina 1

You have accessed anolder version of aParadyne productdocument.Paradyne is no longer asubsidiary of AT&T. Anyreference to AT&TParadyne is amen

Pagina 2 - User’s Guide

iIssue 3 October 19951 IntroductionFeatures 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Important Telephon

Pagina 3 - Warranty

ii Issue 3 October 1995Power Problems 6-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Command Echo Problems 6-2. . . . . . . . . . . .

Pagina 4 - Trademarks

1-1Issue 3 October 19951Congratulations on your purchase of the AT&T DataPort PCXmodem. DataPort PCX modems support high-speed datacommunicati

Pagina 5

Introduction1-2 Issue 3 October 1995Important Telephone NumbersAT&T Paradyne offers a dial-in Bulletin Board System (BBS) thatprovides informat

Pagina 6 - United States

2-1Issue 3 October 19952This Chapter describes how to install an external DataPort PCXmodem (Model 3705).External DataPort PCX Modem PackageYour pa

Pagina 7 - E Issue 3 October 1995

External Modem Installation2-2 Issue 3 October 1995External DataPort PCX Modem InstallationTurn OFF the computer and disconnect the power cord. Bes

Pagina 8

3-1Issue 3 October 19953This chapter describes how to install an internal DataPort PCXmodem (Model 3706).Internal DataPort PCX Modem PackageYour pa

Pagina 9

Internal Modem Installation3-2 Issue 3 October 1995Internal DataPort PCX Modem InstallationUse the following procedure to install your modem into a

Pagina 10 - Issue 3 October 1995

Internal Modem Installation3-3Issue 3 October 1995Installation Procedure1. Turn Off your PC, and unplug it.Also turn off all attached devices, such

Pagina 11

Internal Modem Installation3-4 Issue 3 October 19955. Remove the modem from its shipping bag.!CAUTION:Do not touch the contacts along the bottom ed

Pagina 12 - Features

3705-A2-GB90-20Issue 3October 1995DataPort PCX ModemUser’s GuideAT&T Paradyne Technical Support 800-237-0016AT&T Paradyne BBS 813-532-5254

Pagina 13 - Important Telephone Numbers

Internal Modem Installation3-5Issue 3 October 1995Table 3-1. COM Port and Interrupt Settings COMPort/IRQAddress Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6

Pagina 14 - Modem Package

Internal Modem Installation3-6 Issue 3 October 1995Figure 3-2. Internal Modem Connections

Pagina 15 - Modem Installation

4-1Issue 3 October 19954Software Installation OverviewRPI is the protocol used between your modem and your PC. TheWindows version of the QuickLink

Pagina 16 - Internal DataPort PCX

Testing Your Modem4-2 Issue 3 October 1995If you are installing the DOS version, insert the diskette into yourdisk drive, change to either drive a:

Pagina 17

Testing Your Modem4-3Issue 3 October 19954. Test the modem connection by typing AT and thenpressing Enter.The modem should respond with an OK. This

Pagina 18 - CAUTION:

Testing Your Modem4-4 Issue 3 October 1995If the modem is correctly connected, you will hear a dial toneas the modem goes off-hook, and then the to

Pagina 19

Testing Your Modem4-5Issue 3 October 1995About WinRPIWinRPI provides data compression and error correction forWindows communications and fax applic

Pagina 20

5-1Issue 3 October 19955You can change the way your modem works by using ATcommands. However, your modem’s factory defaultconfiguration works for m

Pagina 21 - 3-6 Issue 3 October 1995

Using AT Commands5-2 Issue 3 October 1995Command mode, use the ATO command. The commandis valid only when RPI is disabled.All commands (except the

Pagina 22 - About WinRPI

6-1Issue 3 October 19956Most modem problems are a result of incorrect cabling orincorrect settings within your communications or fax software.This

Pagina 23 - Testing Your Connections

A Issue 3 October 1995COPYRIGHT 1995 AT&T Paradyne Corporation*All Rights ReservedNoticeChanges and enhancements to the product and to the i

Pagina 24 - Dial-Line Connection Test

Troubleshooting6-2 Issue 3 October 1995S: For an external modem, make sure the AC powertransformer is plugged into an AC power source, itslow-volta

Pagina 25 - 4-4 Issue 3 October 1995

Troubleshooting6-3Issue 3 October 1995S: Make sure that your communications software has a validcharacter format. Valid formats consists of 8 data

Pagina 26 - Software Setup

Troubleshooting6-4 Issue 3 October 1995Answer ProblemsP: Your modem does not answer.S: Make sure the telephone cord is connected to the modem’sLIN

Pagina 27 - AT Command Guidelines

Troubleshooting6-5Issue 3 October 1995P: Your modem answers, but does not connect.S: Make sure that the modem is configured for Automode(ATF0). Thi

Pagina 28 - QuickLink II Fax

Troubleshooting6-6 Issue 3 October 1995S: Your telephone may have Call Waiting enabled. Refer toyour local telephone book for procedures to disable

Pagina 29 - Power Problems

Troubleshooting6-7Issue 3 October 1995S: Set the software’s DTE rate (the speed of the modem-to-computer connection) to a lower speed. (Your softwa

Pagina 30 - Command Echo Problems

Troubleshooting6-8 Issue 3 October 1995P: You are unable to log on to an online service.S: Verify the character structure of the online service and

Pagina 31 - Dial Problems

Troubleshooting6-9Issue 3 October 1995S: Ensure that RPI is enabled both in the software and in themodem (AT+Hn command). QuickLink II Fax automati

Pagina 32 - Connect Problems

A-1Issue 3 October 1995ATable A-1 describes each front panel LED on DataPort PCXexternal modems.Table A-1. LED Descriptions (1 of 2)LEDLabelDescrip

Pagina 33 - Disconnect Problems

Front Panel Status LightsA-2 Issue 3 October 1995Table A-1. LED Descriptions (2 of 2)LEDLabelDescriptionTR Terminal Ready. When ON, the computer is

Pagina 34 - File Transfer Problems

Important Regulatory InformationBIssue 3 October 1995TrademarksAmerica Online is a trademark of American Online, Inc.BitCom and BitFax are register

Pagina 35 - Character Format Problems

B-1Issue 3 October 1995BTable B-1 lists AT commands and S-registers supported by theDataPort PCX modem. This table lists standard AT commandsand S-

Pagina 36 - Rate and Protocol Problems

AT Commands and S-RegistersB-2 Issue 3 October 1995Table B-1. AT Command and S-Register List (2 of 21)AT Command/S-RegisterDescriptionA ANSWER MODE

Pagina 37 - Fax Problems

AT Commands and S-RegistersB-3Issue 3 October 1995Table B-1. AT Command and S-Register List (3 of 21)AT Command/S-RegisterDescription(DIAL COMMAND

Pagina 38

AT Commands and S-RegistersB-4 Issue 3 October 1995Table B-1. AT Command and S-Register List (4 of 21)AT Command/S-RegisterDescriptionDS=nDIAL STOR

Pagina 39 - A-2 Issue 3 October 1995

AT Commands and S-RegistersB-5Issue 3 October 1995Table B-1. AT Command and S-Register List (5 of 21)AT Command/S-RegisterDescriptionHnHOOK CONTROL

Pagina 40

AT Commands and S-RegistersB-6 Issue 3 October 1995Table B-1. AT Command and S-Register List (6 of 21)AT Command/S-RegisterDescriptionMnSPEAKER ON/

Pagina 41 - B-2 Issue 3 October 1995

AT Commands and S-RegistersB-7Issue 3 October 1995Table B-1. AT Command and S-Register List (7 of 21)AT Command/S-RegisterDescriptionQnRESULT CODES

Pagina 42

AT Commands and S-RegistersB-8 Issue 3 October 1995Table B-1. AT Command and S-Register List (8 of 21)AT Command/S-RegisterDescriptionS4=nLINE FEED

Pagina 43 - B-4 Issue 3 October 1995

AT Commands and S-RegistersB-9Issue 3 October 1995Table B-1. AT Command and S-Register List (9 of 21)AT Command/S-RegisterDescriptionS10=nNO CARRIE

Pagina 44

AT Commands and S-RegistersB-10 Issue 3 October 1995Table B-1. AT Command and S-Register List (10 of 21)AT Command/S-RegisterDescriptionS26=nRTS-TO

Pagina 45 - B-6 Issue 3 October 1995

Important Regulatory InformationC Issue 3 October 1995EMI Warnings!WARNING:This equipment has been tested and found to comply with the limits for

Pagina 46

AT Commands and S-RegistersB-11Issue 3 October 1995Table B-1. AT Command and S-Register List (11 of 21)AT Command/S-RegisterDescriptionS95 EXTENDED

Pagina 47 - B-8 Issue 3 October 1995

AT Commands and S-RegistersB-12 Issue 3 October 1995Table B-1. AT Command and S-Register List (12 of 21)AT Command/S-RegisterDescriptionXnEXTENDED

Pagina 48

AT Commands and S-RegistersB-13Issue 3 October 1995Table B-1. AT Command and S-Register List (13 of 21)AT Command/S-RegisterDescriptionZnRESET AND

Pagina 49 - B-10 Issue 3 October 1995

AT Commands and S-RegistersB-14 Issue 3 October 1995Table B-1. AT Command and S-Register List (14 of 21)AT Command/S-RegisterDescription&DnDTR

Pagina 50

AT Commands and S-RegistersB-15Issue 3 October 1995Table B-1. AT Command and S-Register List (15 of 21)AT Command/S-RegisterDescription&FnSELEC

Pagina 51 - B-12 Issue 3 October 1995

AT Commands and S-RegistersB-16 Issue 3 October 1995Table B-1. AT Command and S-Register List (16 of 21)AT Command/S-RegisterDescription&MnASYN

Pagina 52

AT Commands and S-RegistersB-17Issue 3 October 1995Table B-1. AT Command and S-Register List (17 of 21)AT Command/S-RegisterDescription&QnASYNC

Pagina 53 - B-14 Issue 3 October 1995

AT Commands and S-RegistersB-18 Issue 3 October 1995Table B-1. AT Command and S-Register List (18 of 21)AT Command/S-RegisterDescription&TnTEST

Pagina 54

AT Commands and S-RegistersB-19Issue 3 October 1995Table B-1. AT Command and S-Register List (19 of 21)AT Command/S-RegisterDescription&XnTRANS

Pagina 55 - B-16 Issue 3 October 1995

AT Commands and S-RegistersB-20 Issue 3 October 1995Table B-1. AT Command and S-Register List (20 of 21)AT Command/S-RegisterDescription\KnBUFFER C

Pagina 56

Important Regulatory InformationDIssue 3 October 19955. General purpose cables are provided with this product. Special cables,which may be required

Pagina 57 - B-18 Issue 3 October 1995

AT Commands and S-RegistersB-21Issue 3 October 1995Table B-1. AT Command and S-Register List (21 of 21)AT Command/S-RegisterDescription%L LINE SIGN

Pagina 58

C-1Issue 3 October 1995CThis appendix lists the recommended settings for severalcommunications, remote communications, and fax softwarepackages. Re

Pagina 59 - B-20 Issue 3 October 1995

Communications and Fax Software SettingsC-2 Issue 3 October 1995For an external modem, if your serial port is configuredfor 38,400 bps or higher an

Pagina 60

Communications and Fax Software SettingsC-3Issue 3 October 1995Table C-1. Software Configuration GuidelinesConfigurationOptionSetting (If Available

Pagina 61 - Guidelines for All Software

Communications and Fax Software SettingsC-4 Issue 3 October 1995Guidelines for Specific SoftwareThe AT&T Paradyne BBS (813-532-5254) has the la

Pagina 62 - C-2 Issue 3 October 1995

D-1Issue 3 October 1995DTable D-1 lists technical specifications for the DataPort PCXmodem. Table D-2 lists software that supports RPI.Table D-1. D

Pagina 63

Technical SpecificationsD-2 Issue 3 October 1995Table D-1. DataPort PCX Technical Specifications (2 of 3)Specifications DescriptionAC POWERREQUIREM

Pagina 64 - C-4 Issue 3 October 1995

Technical SpecificationsD-3Issue 3 October 1995Table D-1. DataPort PCX Technical Specifications (3 of 3)Specifications DescriptionDATA RATESDial Li

Pagina 65

Technical SpecificationsD-4 Issue 3 October 1995Table D-2. Software That Supports RPIProduct NameMinimum Version CompanyBitComBitFax6.04 (DOS)3.03

Pagina 66 - D-2 Issue 3 October 1995

E-1Issue 3 October 1995EResult codes (Table E-1) are informational messages sent fromthe DataPort PCX modem and displayed on your monitor. Theycan

Pagina 67 - Specifications Description

Important Regulatory InformationE Issue 3 October 19953. The Ringer Equivalence Number (REN) is used to determine the quantity ofdevices which may

Pagina 68 - D-4 Issue 3 October 1995

Result CodesE-2 Issue 3 October 1995Table E-1. DataPort PCX Result Codes (2 of 2)Numbers(ATV0)DescriptionWord(ATV1)11 CONNECT 48001, 4Connection at

Pagina 69

F-1Issue 3 October 1995FWhat is covered:Any defect in material and workmanship.For how long:Five years.What we will do:If your AT&T Paradyne pr

Pagina 70 - E-2 Issue 3 October 1995

Limited WarrantyF-2 Issue 3 October 1995What we ask you to do:Perform warranty registration. Your modem is shipped with oneor both of: auto-registr

Pagina 71 - Limitations:

GL-1Issue 3 October 1995AActiveA nonvolatile configuration area containing the most recentlysaved configuration options.analog signalA type of sign

Pagina 72 - State Law Rights:

GlossaryGL-2 Issue 3 October 1995autobaudModem automatically determines the asynchronous computerdata rate when using AT commands.BBBSBulletin Boar

Pagina 73

GlossaryGL-3Issue 3 October 1995CDCarrier Detect. A signal between the local and remote ends of anetwork indicating that energy exists on the trans

Pagina 74

GlossaryGL-4 Issue 3 October 1995Ddata compressionThe elimination of empty fields, redundancies, and gaps in orderto reduce storage capacity needs

Pagina 75

GlossaryGL-5Issue 3 October 1995DTEData Terminal Equipment. The equipment, such as computersand printers, that provides or creates data.DTRData Ter

Pagina 76

GlossaryGL-6 Issue 3 October 1995fax softwareSoftware installed on a computer that allows a modem to sendand receive facsimiles from another fax mo

Pagina 77

GlossaryGL-7Issue 3 October 1995Llong space disconnectA disconnect can occur if the modem receives an extendedspace from a remote modem; for exampl

Pagina 78

Important Regulatory InformationFIssue 3 October 19958. This modem cannot be used on public coin service provided by thetelephone company. Connecti

Pagina 79

GlossaryGL-8 Issue 3 October 1995on-hookThe state of a telephone or modem that is not being used.Originate modeThe state in which a modem is ready

Pagina 80

GlossaryGL-9Issue 3 October 1995RPI (Rockwell Protocol Interface)A technique for modem/computer communication that permitsdata compression and erro

Pagina 81

GlossaryGL-10 Issue 3 October 1995TterLatin for “thrice.” Used to denote the third version of a standardor recommendation, as in V.27ter.tone diali

Pagina 82

GlossaryGL-11Issue 3 October 1995VV.17A CCITT fax communications standard for modems operatinghalf-duplex with synchronous data at 14,400 bps.V.21A

Pagina 83

GlossaryGL-12 Issue 3 October 1995V.32A CCITT standard for modems operating full-duplex withasynchronous or synchronous data at 9600 or 4800 bps ov

Pagina 84

IN-1Issue 3 October 1995AA/ (Repeat Last Command), B-1Answer (A), B-2Async/Sync Mode (&M), B-16Async/Sync Mode (&Q), B-17AT commands, B-1–B

Pagina 85

IndexIN-2 Issue 3 October 1995BBackspace Character (S5), B-8Baud rate, displaying, B-11Blind Dial Pause Time (S6), B-8Break Forces Escape (\K), B-2

Pagina 86 - IN-2 Issue 3 October 1995

IndexIN-3Issue 3 October 1995FFactory Defaults (&F), B-15fax, modulations supported, D-3FCC registration, D-1features, 1-1flow controlcomputer-

Pagina 87

IndexIN-4 Issue 3 October 1995PP dial modifier, B-2Pause Time for “,” Dial Modifier(S8), B-8power requirements, D-2problemsanswer, 6-4character for

Pagina 88 - IN-4 Issue 3 October 1995

IndexIN-5Issue 3 October 1995S26 (RTS-to-CTS Delay), B-10S36 (Reserved), B-10S37 (Line Connection Speed),B-10S38 (Reserved), B-10S40 (Bit-mapped op

Pagina 89

Important Regulatory InformationG Issue 3 October 1995!CAUTION:Users should not attempt to make such connections themselves, but shouldcontact the

Comentarios a estos manuales