AT&T DEFINITY 7200 series Guía de usuario Pagina 260

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 348
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 259
C-20 TRUNKING TERMS AND CAPABILITIES
_ ___________________________________________________________________________________________________________________________
_ ___________________________________________________________________________________________________________________________
_ ___________________________________________________________________________________________________________________________
_ ______________________________________________________________________________________
SWITCH A
FOR EACH "SWITCH A" TRUNKING OPTION (LISTED BELOW) — REFER TO THE
CORRESPONDING RECOMMENDED "SWITCH B" TRUNK OPTIONS (RIGHT FACING PAGE).
_ ______________________________________________________________________________________
GROUP/CALL TYPE DIREC- SUPERVISION SIGNALING
_ ____________________
TION
________________________________________________________
GENERIC 2, GS LS RB E&M ISDN INCOMING OUTGOING TIMEOUT
SYSTEM 85, OR
DIMENSION PBX "ALERTING" "ADDRESSING" (NOTE 3)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
18/CO OUT D-2 (NOTE 9)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
19/CO 2W D-1
________________________________________________________
Attendant 19
________________________________________________________
Completing/IN 28 AUTO IMMED-START
________________________________________________________
DOD 29 AUTO WINK-START (NOTE 10)
________________________________________________________
20 DMI-MOS DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
20/CO 2W D-2 (NOTE 9)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
21/FX IN D-1
________________________________________________________
Attendant 19
________________________________________________________
Completing 28 AUTO
________________________________________________________
29 AUTO (NOTE 4)
________________________________________________________
20 DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
22/FX OUT D-1
________________________________________________________
DOD 19
________________________________________________________
28 IMMED-START
________________________________________________________
29 WINK-START (NOTE 11)
________________________________________________________
20 DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
23/FX-DOD OUT D-2 (NOTE 9)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
24/FX 2W D-1
________________________________________________________
Attendant 19
________________________________________________________
Completing 28 AUTO IMMED-START
________________________________________________________
IN/DID 29 AUTO WINK-START (NOTE 4)
________________________________________________________
20 DMI-MOS DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
25/FX 2W D-2 (NOTE 9)
_ ______________________________________________________________________________________
Notes:
9. To be used with CO applications that provide a "party test" signal toward the PBX.
10. This trunk type and optional signaling arrangement may be used to build a "Special Access" trunk group. Although other trunk
group types may be more appropriate, this trunk group signaling arrangement may function to provide trunking facilities for
MEGACOM Service.
Vista de pagina 259
1 2 ... 255 256 257 258 259 260 261 262 263 264 265 ... 347 348

Comentarios a estos manuales

Sin comentarios